| Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments (Administrator) |
|---|---|---|---|---|---|
| EQP.10 | Determination of useful storage volume and heat loss | EN 12897:2006* (sections 6.2.2 and 6.2.7 and Annex B); Regulation (EU) No. 812/2013 of 18 February 2013 (point 2 of Annex II and Annex IX) | Hot water tanks | The normative document indicated with * is void, and its tecnical validity is not in question. | |
| EQP.14 | Storage volume and heat loss determination of hot water tanks | EN 15332:2007 - ponto 5.4; Regulamento Delegado (UE) Nº 812/2013 | Hot water tanks | ||
| EQP.15 | Electrical Safety | EN IEC 60335-1, IEC 60335-1, EN IEC 60335-2-40, IEC 60335-2-40 | Heat pumps for DHW | EN IEC 60335-1:2023; EN IEC 60335-1:2023/A11:2023 IEC 60335-1:2020; IEC 60335-1:2020/COR1:2021 (except Sections 8.1.4, 15.1.1, tests IPx1, IPx2 and IPx9, sections 19.11.4, 22.32, 25.14 and Annexes J, R, N and U) EN IEC 60335-2-40:2024; EN IEC 60335-2-40:2024/A11:2024 IEC 60335-2-40:2024 (except flammable gases, Sections 21.101 and 32 and Annexes FF, GG, KK, LL, MM, NN, PP and QQ) |